An infrared frame is not bonded to your display. It clamps on from the outside, so the relationship between the beam grid and the pixels behind it is a physical fact that has to be measured once and stored. That measurement is calibration — and it lives in the controller, not in the operating system.

Two technologies, two answers

Infrared measures, capacitive tunes

Infrared needs calibration because the sensor and the display are two separate objects that are aligned by hand. Four corners of a frame can be 2 mm off from where the drawing says they are, and the beam grid has no way of knowing — so the tool asks you to touch known points and solves for the mapping.

A capacitive panel needs no calibration because the sensor is bonded to the glass and the glass is cut to the housing. The coordinates are where the electrodes are. What a capacitive panel sometimes needs is tuning: four firmware parameters that decide how sensitive it is, how fast it reports and how it behaves at the edges. Same tool family, different tab, different purpose.

Rule of thumb: if the error changes across the screen — small in one corner, large in the other — it is calibration. If the error is the same everywhere, it is display scaling, mounting or the orientation bit.
The calibration run

Four points, nine, or twenty-five

The tool offers three densities, and the right one depends on how much accuracy the application needs and how patient the operator is.

ModeTimeUse it forResult
4-point20 secondsKiosks, signage, anything where a finger targets a 40 mm buttonSolves origin, scale and rotation. Fastest, and adequate for 90 % of installs
9-point45 secondsMeeting boards and whiteboards where people drawAdds per-axis linearity correction; removes the bow that shows up mid-edge
25-point2 minutesLarge format above 86 inch, curved frames, anything with unusual glassMaps local distortion across the surface, including the sag a long extrusion develops
When to do it again

Recalibrate, or leave it alone

EventRecalibrate?Why
First installationAlwaysThe frame clamps on the outside, so the mapping depends on how it sits on this particular display.
After replacing a controller or an LED tubeAlwaysThe new board has no profile, or the old profile describes a different beam grid.
After the unit is moved, or the display is taken off the wallAlwaysRemoving and refitting changes the frame's position by a millimetre or two, which is 3–5 mm on the far corner.
After changing the cover glass thicknessAlwaysGlass refracts the beams; a 3 mm change shifts the far-corner mapping.
After rotating the frame 90°Always, plus the orientation bitWithout the orientation bit the axes swap and the cursor moves sideways.
After an OS update or a driver changeNeverCalibration lives in the controller, not in the operating system. An OS update cannot lose it.
After cleaning the glassNoUnless something was left on the surface during the original calibration.
The software

What we send, and what it does

Every order ships with the calibration tool and the profile file for the size you bought. It is not a download from a support portal that asks you to register — it comes attached to the order email, and again on request for as long as you own the unit.

  • Windows tool — 32 and 64-bit builds for Windows 7 through 11. Runs from a folder, no installer, no admin rights needed for calibration.
  • Linux command line — for kiosk images and Yocto builds where installing a GUI is not an option. Reads the same profile format.
  • Profile export and import — .cal files, so a production line can clone one good unit into a batch, or a field engineer can email you a profile to reflash.
  • Diagnostics tab — live beam map. A blocked or dead LED pair shows as a missing line before it becomes a customer complaint, which is how you tell a dirty filter strip from a failed tube.
  • Firmware and descriptor tools — for reflashing a controller that enumerated as a mouse, or changing the touch-point count on a spare board.

If your integration needs the protocol rather than the GUI — for example, calibrating inside your own production test software — ask for the command reference. We send it to integrators who are building the frame into their own line.

Remote calibration

Ten minutes, shared screen

For first-time installs we do the run together rather than describing it. It is faster than writing instructions, and it catches the two mistakes that make calibration fail: touching the frame instead of the glass, and calibrating before the frame is finally fixed.

01

Send the size and a time window

Plus your timezone. We reply with a slot and the tool build for your Windows version, if you do not already have it.

02

Connect the frame and open Device Manager

The device must read “HID-compliant touch screen”. If it reads “mouse”, we sort the descriptor first — calibration cannot fix that.

03

Screen share, then touch where we point

Four corners, then nine if the application draws. You will see the cursor land as each point is accepted.

04

Check the corners and the edges

A finger dragged 5 mm inside each border. This is where a frame that passed four points still fails.

05

Save, then power-cycle

The profile is written to EEPROM. Pull the USB, plug it back in, and confirm the corners still land — that proves the save, not just the session.

Capacitive tuning

Four parameters, not a calibration

A capacitive panel does not have a calibration step. If a customer reports that theirs “needs calibrating”, the actual fix is almost always one of these four numbers, changed in the settings file and written to the controller.

ParameterWhat it doesWhen to change it
Touch thresholdHow much capacitance change counts as a touchRaise it for thick cover glass or a gloved hand; lower it if a panel misses light taps
Report rateHow often positions are sent, 60–200 HzLower it for long or noisy cables, raise it for drawing and whiteboard use
Edge suppressionDead band at the border, 1–5 mmIncrease it if the housing presses on the sensor; too much kills buttons at the edge
ESD recovery levelHow the controller recovers after a dischargeHigher levels recover faster on outdoor units, at the cost of a brief touch dropout
What calibration cannot fix

Be honest about the ceiling

SymptomReal causeThe actual fix
Dead stripe down one sideA failed LED tube, or a glass edge crossing the beamReplace the tube or move the glass — calibration cannot create a beam that is not there
Cursor drifts a few millimetres after a rebootThe controller is not saving the profile, or the OS applies its own scalingCheck the profile is written to EEPROM; check display scaling is 100 %
Touch works but the position is invertedX/Y swapped or the orientation bit is wrongSet orientation in the tool, not in the OS
Jitter only in humid weatherCondensation on the filter stripClean and reseal; a gasket problem, not a calibration problem
Ghost touches with nothing touchingGrounding, or ambient IR from sunlight or a heaterFix the ground first, then consider the high-immunity tube set
FAQ

Calibration questions

Do I need to calibrate a capacitive panel?
No. A capacitive panel is bonded to a fixed grid; the coordinates are geometric, not measured. What you may need is firmware tuning — threshold, report rate, edge suppression and ESD level — which is a settings file, not a calibration run. We send the file matched to your glass stack.
Where is the calibration stored?
In the controller's EEPROM. It survives power cycles, cable swaps and OS reinstalls, and it travels with the frame if you move it to another machine. That is also why a replacement controller arrives blank and has to be calibrated once.
Can I calibrate a batch on the production line?
Yes, and it is the fastest way to make units behave identically. Calibrate one frame, export the profile as a file, then write the same profile to every frame of the same size and batch. Differences between units at that point are mechanical, not electronic.
Can you calibrate it for me remotely?
That is what most first-time customers do. A Windows PC, the USB cable and a video call — ten to fifteen minutes. We watch the cursor, tell you which point to touch, and confirm each corner before moving on. No software installation on your side beyond running the tool we send.
The cursor is offset by a constant amount everywhere. Is that calibration?
A constant offset in one direction is usually not calibration — it is the display scaling set to 125 % or 150 % in Windows, or a frame that is sitting a few millimetres off its bracket. Uniform offset means the mapping is right but the origin moved; check scaling before you recalibrate.
What if the tool does not see the controller?
Almost always the port or the cable. Try a port on the back of the machine rather than a front-panel hub, then a different cable, then check Device Manager for a device with a warning triangle. If the controller enumerates as a mouse, it needs a reflash before the tool will talk to it.

Calibration problem? Send the beam map.

Connect the frame, open the diagnostics tab and screenshot the beam map. That image tells us in one look whether it is calibration, a tube, a cable or the ground.